Smart Power Management Dedicated interface: For generator connection, smart load management, or AC coupling UPS-level switching <10ms Single-phase parallel connections: Supports up to 6 pcs
User Experience LED/LCD display Smart APP: User-friendly operation and monitoring
Specification
Rated Output Power (W)
:
3000W
Battery Nominal DC Voltage
:
48Vdc
Max. PV Input DC Voltage
:
580V
MPPT Voltage Range
:
100-550V
Max. PV Array Input Current
:
16A
Phase
:
Single phase
Dimension (DxWxH)
:
222.5 × 558.1 × 455.1mm
Net Weight
:
28.1Kg
Battery input (DC)
:
Battery type
:
Lithium battery/Lead-acid battery
Voltage range
:
42-63V
Charging rule
:
3-stage charging or BMS command
Max. charging and discharging current
:
75A
PV input (DC)
:
Max. input power
:
4500W
Start-up voltage
:
100V
Rated input voltage
:
360V
Number of MPPTs
:
1
Number of strings per MPPT
:
1
AC output (On-grid)
:
Max. output apparent power
:
3300VA
Rated output current
:
14.3A
Max. input current from grid
:
28.6A
Rated output voltage
:
230V
Rated grid frequency
:
50Hz
THDi
:
<3%
Power factor
:
≈1 (Adjustable from 0.8 leading to 0.8 lagging)
AC output (Off-grid)
:
Peak power (VA), time(s)
:
1.5* Rated power, 60s
Overload power (VA), time(s)
:
1.25* Rated power, 300s
Rated output current
:
13.1A
Rated output voltage
:
230V
Rated output frequency
:
50/60Hz
THDu (@Linear loads)
:
<3%
Switch time
:
10ms
Efficiency
:
Max. Efficiency
:
97.60%
European Efficiency
:
97.20%
Max. discharging efficiency
:
94.60%
Protection
:
Basic protection
:
PV reverse polarity, AC output overvoltage, Anti-islanding, PV insulation resistance, AC output overcurrent, Grid monitoring, PV string current monitoring, AC output short circuit, Residual current (RCD) detection
Smart Power Management Dedicated interface: For generator connection, smart load management, or AC coupling UPS-level switching <10ms Single-phase parallel connections: Supports up to 6 pcs