UPS Online Sinewave

SE6102C33

60.000VA / 60.000W | 138 ~ 485Vac

ICA UPS SE6102C33 Capacity 60.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.

Key Features

Reliable Power for Various Applications

Auto Charging at Off Mode

Auto-Restart Function

Cost Effective Solution

Specification

Capacity

:

60.000VA / 60.000W
AC Input Voltage

:

138 ~ 485Vac
Inverter Output Voltage

:

380 / 400 / 415Vac (3Ph+N+PE)
Inverter Output Waveform

:

Inverter Output Efficiency

:

95.5%
Transfer Time

:

Utility to Battery: 0ms; Utility to Bypass: 0ms
Dimension (L x W x H)

:

828 x 250 x 868mm
Net Weight

:

83Kg
Nominal Voltage

:

380 / 400 / 415Vac (3Ph+N+PE)
Operating Frequency Range

:

40Hz – 70Hz (50/60Hz Auto-Sensing)
Power Factor

:

≥0.99
Bypass Voltage Range

:

220Vac Max. voltage: +25% (optional +10%, +15%, +20%)
230Vac Max. voltage: +20% (optional +10%, +15%)
240Vac Max. voltage: +15% (optional +10%)
Min. voltage: -45% (optional -20%, -30%)
Bypass Frequency Range

:

Frequency synchronize tracing range: ±10%
ECO Range

:

Same as bypass
Harmonic Distortion (THD)

:

≤3% (100% non-linear load)
BATTERY

:

Battery Voltage

:

±240Vdc
Backup Time

:

6 ~ 10 minutes
Charge Current(A) (Charger current can be set according to battery capacity installed)

:

Max. current 20A
Backup Configuration

:

External
OUTPUT

:

Power Factor

:

1.0
Voltage Regulation

:

±1%
Frequency Line Mode

:

±1%/ ±2%/ ±4%/ ±5%/ ±10% of the rated frequency (optional)
Frequency Bat. Mode

:

50/60 (±0.2)Hz
Crest Factor

:

3:1
Harmonic Distortion (THD)

:

≤2% with linear load, ≤4% with non-linear load
SYSTEM FEATURES

:

Protection

:

Short circuit, Overload, Over temperature, Battery low, Fan fault alarm
Overload

:

Load ≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min
Short Circuit

:

Hold Whole System
Communication

:

USB, RS232, RS485, Parallel port, REPO port, LBS port, dry contact, Intelligent slot, SNMP card (optional), Relay card (optional)
Backfeed Protection

:

Support
Remote LCD

:

Support
ENVIRONMENTAL

:

Operating Temperature

:

0 ~ 40ºC
Storage Temperature

:

-25 ~ 55ºC (No battery)
Humidity Range

:

0 ~ 95% (Non-condesing)
Altitude

:

1500m, lower the rated power for use
Noise Level

:

<58dB
PHYSICAL UPS Without External Battery (UPS Only)
STANDARDS

:

Safety

:

IEC/EN62040-1, IEC/EN60950-1
EMC

:

IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

Key Features

Reliable Power for Various Applications

Auto Charging at Off Mode

Auto-Restart Function

Cost Effective Solution